Power on the IDEXX VetLab Station. Ensure all analyzer icons (except Catalyst Dx) are present with a “Ready” status. Then, power on the Catalyst Dx analyzer. Once the Catalyst Dx Home screen displays and its icon displays on the IDEXX VetLab Station Home screen, your connections are complete.

How do I use idexx catalyst?

Power on the IDEXX VetLab Station. Ensure all analyzer icons (except Catalyst Dx) are present with a “Ready” status. Then, power on the Catalyst Dx analyzer. Once the Catalyst Dx Home screen displays and its icon displays on the IDEXX VetLab Station Home screen, your connections are complete.

How long is serum good for Idexx?

The DBS samples are stable for at least 7 days when stored at room temperature.

How do you run a dilution on a Catalyst?

Accurately measure the desired amount of sample to be diluted and gently transfer it to a sample cup. Then, accurately measure an equal amount of diluent (0.9% saline) and transfer it to the sample. 2. Thoroughly mix the sample and diluent, ensuring there are no bubbles in the mixed sample.

How do I turn on Idexx catalyst?

Do one of the following: • Tap the Catalyst One icon on the IDEXX VetLab Station Home screen. Tap the alert message in the title bar to display the alert message. Follow the instructions displayed in the alert message. The Catalyst One analyzer works in conjunction with the IDEXX VetLab Station.

How do you read a dog urinalysis?

Interpretation of a UP:UC is as follows: <0.5:1 (dogs) and <0.4:1 (cats) is normal, 0.4 or 0.5–1:1 is questionable, and >1:1 is abnormal. With primary renal azotemia, a UP:UC >0.5:1 in dogs and >0.4:1 in cats is considered abnormal.

How do you collect UPC urine?

Gloves are encouraged for collection since there may be some spilling of urine. Select a small, clean plastic or glass container that can be sealed shut. Another option is using a ladle spoon or a larger container to facilitate urine collection, then later transfer urine to a small container.

How do you run a dilution on Idexx SediVue?

Remix the diluted sample and run it on the SediVue Dx analyzer. Does the clarity of the sample suggest high amount of cells, bacteria, crystals, or debris? 1. On the Select Instruments screen, tap Run Dilution, specify the desired dilution factor (total parts), and tap Run.

How do I dispose of Idexx reagent kit?

Carefully remove each reagent bottle from the old reagent kit and dispose of the contents of each bottle according to applicable local disposal laws. Then place the caps from the bottles in the new reagent kit onto the bottles in the old reagent kit.

How do you dilute a blood sample?

By use of a tonometer, whole blood samples were adjusted to 1 of 3 oxygen concentrations (40, 100, or 600 mm Hg) and the PO2 values were measured at baseline and subsequent to the 4 heparin dilutions. Results: The 4 syringe techniques resulted in 3.9%, 9.4%, 18.8%, and 34.1% dilutions of a 1-mL blood sample.

Article first time published on

Do you spin EDTA tubes?

Pink-top tube (EDTA) These tubes are preferred for blood bank tests. NOTE: After the tube has been filled with blood, immediately invert the tube 8-10 times to mix and ensure adequate anticoagulation of the specimen.

What tube is used for hematology?

5. EDTA – Tube used for hematology studies.

What color tubes are used for which tests in phlebotomy?

STOPPER COLORCONTENTSUSES/COMMENTSGreenSodium heparin(100 USP Units)Ammonia, Lactate, HLA TypingTanK2 EDTALead levelsYellowACD Solution A consists of trisodium citrate, citric acid and dextroseDNA Studies, HIV CulturesPink(K2)EDTABlood type & Screen, Compatibility Study, Direct Coombs HIV Viral Load

What is a catalyst Chem 10 clip?

Chem 10 CLIP A focused chemistry foundation; combine with a CBC, electrolytes, and other tests such as SDMA. Use albumin level to guide safe administration of anesthesia. ALB. ALB/GLOB. ALKP.

What is idexx CBC?

IDEXX CBC typically used for preventive care screening Available for canine, feline, and equine patients, this option provides an automated CBC, including hemogram, five-part differential, platelets, platelet indices, as well as (for canine and feline patients) reticulocyte count and reticulocyte hemoglobin.

How do you clean SediVue?

1. On the SediVue Dx Settings screen, tap Clean and then tap Turn Off SediVue. 4. Using a new rinsed alcohol prep pad, clean the left side of the pusher arm 5 times (ensuring the right edge of the track is cleaned thoroughly), and then dry it with a new dry optical tissue.

What does a high UPC mean?

The UPC Ratio has shown a significant correlation with the morbidity of the patient—the higher the UPC ratio value, the worse the prognosis.

What is a normal UPC?

Urinary Protein to Creatinine Ratio (UPC) A UPC < 0.2 is normal for most dogs and cats. Borderline values are from 0.2 to < 0.4 for the cat and from 0.2 to < 0.5 for the dog. Values ≥ 0.4 for the cat and ≥ 0.5 for the dog are considered proteinuric.

What does a UPC test for?

The urine protein:creatinine (UPC) ratio is a simple test that measures how much protein is being lost through the kidneys. It is used to determine whether a pet may have serious kidney disease (see handout “Urine Protein”).

What does low pH in dog urine mean?

In healthy pets, the urine pH is typically in the 6.5 to 7.0 range. If the pH is acidic (pH below 6) or alkaline (pH above 7) it may allow bacteria to thrive and crystals or stones to form. However, do not be alarmed if your pet’s urine pH is not 6.5.

What causes high pH dogs?

High levels of certain minerals in dog food can increase the chance of crystal formation in urine. Magnesium and phosphate are mineral components of the most common crystal type struvite. Don’t feed a dog food with excessive amounts of these minerals. The dog food your dog eats also influences urine acidity (pH).

How can I lower the pH of my dogs urine?

Typically diets high in meat protein will help contribute to a lower pH. Dog urine often falls around 7-7.5 on most urine samples I evaluate in practice. But some certainly go a little higher than that, into the 8.0 or 8.5 range.

How do I clean and calibrate idexx catalyst 1?

1. Tap the Catalyst One icon on the IDEXX VetLab Station Home screen. 2. Tap Maintenance, tap Clean, and follow these on-screen instructions.

How do you clean a catalyst DX?

To Clean the Internal Components On the Catalyst Dx* touch screen, tap Tools and then tap Clean Analyzer.

What does a catalyst machine do?

During a chemical reaction, the bonds between the atoms in molecules are broken, rearranged, and rebuilt, recombining the atoms into new molecules. … As a result, catalysts make it easier for atoms to break and form chemical bonds to produce new combinations and new substances.

How do I clean my idexx snap pro?

Clean the entire base using a lint- free wipe or cotton swab dampened with 70% isopropyl alcohol, mild liquid soap and water, or a 10% bleach solution. locking the base and fasteners properly can impact analyzer performance.

What is snap pro?

SNAPCHAT has a new app on the way called Snap Pro that’s packed with exclusive perks. As its name suggests, the release is aimed at power users of the main app, giving them the ability to create new profiles and check in-depth stats on how many people are viewing their Stories.

What is idexx snap pro?

The SNAP Pro Analyzer automatically activates, times, and interprets your SNAP test results for you. … Connect for the benefits of two-way integration: reduce missed charges and automatically include results in your patients’ medical records.

How do you use SediVue idexx?

Add approximately 0.5 cc of air to the syringe, and then slowly invert the syringe 10 times, ensuring the urine is mixed thoroughly. IMMEDIATELY after inversion, purge all the air from the syringe and inject 165 µL of urine into the cartridge fill port.

How do you change a SediVue cartridge?

1. Tap the SediVue Dx icon on the IDEXX VetLab Station Home screen and then tap Replace Cartridges. OR Tap Replace Cartridges in the alert message.

How much does a SediVue cost?

The cost of a patient run on the SediVue Dx analyzer is $15.25 and a QC run is $5.50 per level or $11.00 total.